Treatment of infection caused by animal commensal pathogen Staphylococcus simulans

Authors

  • Thamer A Almangour Department of Clinical Pharmacy, College of Pharmacy, King Saud University, PO Box 2457, Riyadh 11451, Saudi Arabia https://orcid.org/0000-0003-1508-8693
  • Abeer A Alanazi Clinical Pharmacy Services, King Saud University Medical City, King Saud University, Riyadh 11451, Saudi Arabia
  • Sarah T Al Dughaish Pharmacy department, King Khaled Eye Specialist Hospital and Research Center, Riyadh, Saudi Arabia https://orcid.org/0009-0005-2544-6361
  • Fahad M Al Majid Division of Infectious Diseases, Department of Internal Medicine, College of Medicine, King Saud University, PO Box 7805, Riyadh 11472, Saudi Arabia

DOI:

https://doi.org/10.3855/jidc.22148

Keywords:

bacteremia, animal pathogen, Staphylococcus simulans, coagulase-negative staphylococci, case report

Abstract

Introduction: Staphylococcus simulans is an animal pathogen belonging to the coagulase-negative staphylococci (CoNS) group that was occasionally identified in the skin of healthy people. Although it was suggested that S. simulans share some virulence factors with S. aureus, little is known about human infections, and clinical relevance is limited to a few reports. Herein, we report a case of bacteremia caused by S. simulans.

Case presentation: A 39-year-old man was brought to the hospital due to heart attack. During the course of admission, his procalcitonin, C-reactive protein, and erythrocyte sedimentation rate were elevated. He was empirically started on vancomycin and meropenem. However, meropenem was discontinued after the identification of the fact that S. simulans was susceptible to oxacillin, as well as the identification of Streptococcus mitis in blood culture. Repeat blood culture a day after antibiotic initiation was persistently positive for S. simulans only, while the second repeat blood culture 3 days after antibiotic initiation was negative. The patient remained hemodynamically stable, and the laboratory values were back to normal. He continued the antibiotic course for a total of 14 days and was discharged in stable condition.

Conclusions: CoNS should not be easily discarded as a sample contaminant and pathogen identification to species level is crucial. Clinicians should be aware of the virulence potential of S. simulans.

Downloads

Published

2026-07-31

How to Cite

1.
Almangour TA, Alanazi AA, Al Dughaish ST, Al Majid FM (2026) Treatment of infection caused by animal commensal pathogen Staphylococcus simulans. J Infect Dev Ctries 20:1093–1098. doi: 10.3855/jidc.22148

Issue

Section

Case Reports