TB LAMP assay, a beneficial tool for the diagnosis of Tubercular meningitis in resource-limited settings

Authors

  • Vineeta Mittal Department of Microbiology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, India https://orcid.org/0000-0002-9311-9240
  • Manoj Kumar Department of Microbiology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, India https://orcid.org/0009-0002-5817-4217
  • Ajay Kumar Singh Department of Neurology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, India

DOI:

https://doi.org/10.3855/jidc.18115

Keywords:

CSF, TB LAMP, MGIT, TBM, Xpert, ZN Smear

Abstract

Introduction: Tubercular meningitis (TBM) is a serious public health problem in developing countries as it leads to significant mortality and residual neurological sequelae. The estimated mortality due to TBM in India is 1.5 per 100,000 population. In resource-limited settings, only the Ziehl-Neelsen (ZN) stain, which has very little sensitivity, is available. The World Health Organization recommended the Loop Mediated Isothermal Amplification (TB LAMP) assay for pulmonary tuberculosis only. We evaluated this test for tubercular meningitis as well.

Methodology: In a cross-sectional study of 2-year duration, we have taken 239 cerebrospinal fluid samples from suspected cases of tubercular meningitis patients. ZN staining along with Mycobacteria Growth Indicator Tube (MGIT) TB culture, Xpert MTB/RIF Ultra assay, and commercial TB LAMP assay were performed for each sample.

Results: Out of 239 samples, 40 samples (16.73%) were found TB LAMP assay positive, 48 samples (20.08%) were found Xpert ultra-assay positive, 12 samples (5.02%) were MGIT TB culture positive and acid-fast bacillus smear positive in ten samples (4.18 %). Out of 12 MGIT-positive samples, all samples (100%) were TB LAMP and Xpert ultra positive and one sample (8.33%) was ZN smear positive. In 199 negative samples from the TB LAMP assay, eight samples were positive by Xpert, none by MGIT TB culture and AFB smear. Sensitivity and specificity were found as 100% and 87.66%, respectively, for the TB LAMP assay.

Conclusion: TB LAMP assay is a rapid, cost-effective, sensitive, and specific test for tubercular meningitis infection in resource-limited settings.

Author Biographies

Vineeta Mittal, Department of Microbiology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, India

Professor Department of Microbiology, Dr Ram  Manohar Lohia Institute of medical Sciences Lucknow India

Manoj Kumar, Department of Microbiology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, India

Junior resident, Department of Microbiology,  Dr Ram Manohar Lohia Institute of medical Sciences, Lucknow, India

Ajay Kumar Singh, Department of Neurology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, India

Professor and head, Department of Neurology, Dr Ram Manohar Lohia Institute of medical Sciences, Lucknow, India

Downloads

Published

2024-03-31

How to Cite

1.
Mittal V, Kumar M, Singh AK (2024) TB LAMP assay, a beneficial tool for the diagnosis of Tubercular meningitis in resource-limited settings. J Infect Dev Ctries 18:435–440. doi: 10.3855/jidc.18115

Issue

Section

Original Articles