Utility of nano-impregnated surface coating to achieve continuous active disinfection in ICU of a tertiary trauma center

Authors

  • Sharin Varma Department of Microbiology, Jai Prakash Narayan Apex Trauma Centre, All India Institute of Medical Sciences, New Delhi, India https://orcid.org/0000-0002-1637-7043
  • Nirupam Madaan Department of Hospital Administration, Jai Prakash Narayan Apex Trauma Centre, All India Institute of Medical Sciences, New Delhi, India
  • Purva Mathur Department of Laboratory Medicine, Jai Prakash Narayan Apex Trauma Centre, All India Institute of Medical Sciences, New Delhi, India
  • Aparna Ningombam Department of Laboratory Medicine, Jai Prakash Narayan Apex Trauma Centre, All India Institute of Medical Sciences, New Delhi, India
  • Rajesh Malhotra Department of Orthopedics, Jai Prakash Narayan Apex Trauma Centre, All India Institute of Medical Sciences, New Delhi, India
  • Ganga Prasad Department of Anesthesiology Pain Medicine and Critical Care, Jai Prakash Narayan Apex Trauma Centre, All India Institute of Medical Sciences, New Delhi, India https://orcid.org/0000-0002-1178-4643

DOI:

https://doi.org/10.3855/jidc.21290

Keywords:

infection control, hospital acquired infection, continuous active disinfection, antimicrobial, coating, decontamination

Abstract

Introduction: Implementing continuous active disinfection presents challenges as conventional cleaning methods may not fully mitigate risks. Hence, evaluating innovative technologies becomes imperative. This study assessed a nanoparticle-based surface coating containing titanium dioxide engineered into nano-molecules that is activated by normal light and provides ongoing disinfection.

Methodology: The research took place in two intensive care units (ICUs): ICU A (coated) and ICU B (control). Data on healthcare-associated infections (HAIs) and environmental factors were collected pre- and post-coating application to gauge its impact. The change in percentage of positive swabs/HAI cases in ICU A was compared to ICU B and statistically analyzed using a 2-sample test for equality of proportions.

Results: ICU A witnessed a 26.5% decrease in positive environment swabs post-coating, while ICU B saw a 160.9% increase. This disparity was statistically significant (p = 0.000). Both ICUs experienced decreased ventilator associated pneumonia (VAP) cases, though central line associated-blood steam infection (CLA-BSI) and catheter associated urinary tract infection (CAUTI) cases increased in ICU A post application. Following coating, positive environmental swabs and VAP decreased by 71.8%, and 72.5%, while CLA-BSI and CAUTI increased by 198% and 43.5%.

Conclusions: The evaluation showed that the coating may serve to supplement traditional cleaning and disinfection methods. Further research into the efficacy and cost-effectiveness of such antimicrobial coating is needed for overall improvement in patient care.

Downloads

Published

2026-09-30

How to Cite

1.
Varma S, Madaan N, Mathur P, Ningombam A, Malhotra R, Prasad G (2026) Utility of nano-impregnated surface coating to achieve continuous active disinfection in ICU of a tertiary trauma center. J Infect Dev Ctries 20:1361–1367. doi: 10.3855/jidc.21290

Issue

Section

Original Articles